38K subscribers in the ecobee community. A subreddit for ecobee and all their smart home products. Skip to main content. ... My fan is not running the whole time I am in "home" mode. Min fan runtime is 15 min, but the AC runs more than that each hour anyway. When the AC is off, so is the fan, and the unit reflects that under "equipment running".

support.ecobee.comThis looks at the reported current operation mode. Any value of this new sensor of 1 or more indicates the fan is running. 0 indicates the entire HVAC is idle. 1 indicates only the fan is running (fan on, in hold) 2 indicates it's heating. 3 indicates it's cooling. This works in all control modes (if the ecobee was being controlled locally, by ...

Did you know?

From looks to performance, the new ecobee Smart Thermostat Premium does a whole lot to make up for the $250 price tag. But even with all that this thermostat can do, it does it all extremely well ...I have a VB script in Homeseer that calculates the standard deviation across my 4 Ecobee temp sensors every 15 minutes. If the standard deviation between all the sensors is less than 1 deg, then set Ecobee minimum fan runtime to 5 mins/hr. If between 1.1 and 1.7 deg, then run fan for 20 mins/hr. If over 1.8, then run fan full time.Auto: Enable fan when the system is actively heating or cooling your home, or to satisfy the Minimum Fan Runtime setting (page 12). On Thermostat and Mobile: Select Main Menu > Quick Changes > Fan. On Web: Select Fan tile. Minimum Fan Runtime (Auto mode only) When the fan is in Auto mode, ecobee3 operates it according to the Minimum Fan Runtime ...

Huh. I didn’t realize this. I used to have a Nest and it performed as you expect. If you said 20 min/hour, and the system didn’t cycle at all, it would run the fan 20 mins every hour. If the system cycled (heat or air), that cycle time was counted as part of the 20 mins. Hopefully Ecobee devs make this an option.On the ecobee App. Tap Home > Tap on the Thermostat > Tap the Menu > Tap on eco+ then drag the slider to your desired saving level. If an eco+ feature is running at an inconvenient time, you may temporarily disable eco+. On the thermostat home screen. Tap the Arrow icon next to " eco+ is on " and select End eco+ for today.Fan Hold - in the Quick Changes panel (tap lower right button which looks like 2 switches. Hold the Fan On for short term. 15 min - Indefinite. Settings/System - Set a minimum runtime per hour. 5. Reply. Gortexal. • 2 days ago. The app does leave much to be desired.Track HVAC Runtime. Edit: Thanks for the help - Combined a custom graph card, and the historical sensors into a vertical stack card to get the thermostat control and runtimes showing. I'm currently running the Honeywell TCC integration, and I have templates setup to pull a status of the HVAC system into a panel, but what im stuck on is tracking ...

I am using an ecobee with voice to control a heat only system on a 2 story house. I like using the fan runtime to equalize the temperature difference between the floors. On a cool day I can get away with setting to 5min but on hotter days it works best at 15 or more.Check Your Minimum Fan Runtime · Runtime settings of 15 minutes or less: The Ecobee Thermostat will divide the time into two equal sessions of fan running time ... ….

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs. Ecobee fan runtime. Possible cause: Not clear ecobee fan runtime.

Read Also: What Is Fan Runtime on Ecobee? Recommended Settings & Minimum Runtime. Contact Ecobee Support First Before an HVAC Professional. If you are an Ecobee customer, they provide free support. So, unless you have an HVAC emergency, I'd recommend contacting Ecobee first to try and get your issues resolved. Having HVAC service people out ...Possible Reasons for Power Loss: Interruptions to the 24VAC power supply can cause the thermostat to go black or reboot during heating or cooling calls. HVAC safety features, such as a high-limit switch, or float switch, might trigger power cuts to prevent equipment damage. Inadequate transformer VA rating can lead to power loss, especially ...Smart Thermostat Premium works with most centralized residential heating and cooling systems. Heating: Up to 2 stages. Cooling: Up to 2 stages. Heat pumps: Air, Water, and Geothermal with up to 2 stages, and 2 stages of AUX heat. Accessories: Dehumidifier, humidifier, or ventilation device. Fan coil units: 2- and 4-Pipe with up to 3 fan speeds.

Their documentation and examples state if the heating/cooling doesn't run during the hour the ecobee should run the fan for four equal 2:30s blocks every fifteen minutes. This isn't what I am seeing. What is actually happening is the fan is running for two blocks of 5 minutes. One at the beginning of the hour and one in the middle of the hour.Ecobee, on the other hand, seems to do it not with a schedule but by setting a minimum run time of 5-55 min per hour. Looks like you can do a one-time run in increments of 15 minutes. ecobee Fan Runtime Explained (9 Key Things To Know) Fan settings on the ecobee Thermostat. Had I known this, I probably would have bought the Ecobee. 🤷‍♂️

actors on carshield commercial Ecobee recommends setting your router to channels 1, 6, 9, or 11, as these don't overlap with other channels. Distance. If an ecobee sensor is placed too far away from the device hub (AKA the ecobee thermostat), it may struggle to communicate. This could result in a pattern of "unavailable" status updates from that particular sensor.Those runtimes contribute to fan runtime, so if your heat or cool runs for 30 minutes in an hour, your fan will not separately run another 30 minutes within the hour. I would suggest setting the minimum runtime to 0 min/hr when you're using cooling, otherwise the fan will redistribute the coil's moisture into the air and increase humidity. chicano block letterstic tac toe glow unblocked On the ecobee App. Tap Home > Tap on the Thermostat > Tap the Menu > Tap on eco+ then drag the slider to your desired saving level. If an eco+ feature is running at an inconvenient time, you may temporarily disable eco+. On the thermostat home screen. Tap the Arrow icon next to " eco+ is on " and select End eco+ for today. papa murphy's pizza coupons printable I am using an ecobee with voice to control a heat only system on a 2 story house. I like using the fan runtime to equalize the temperature difference between the floors. On a cool day I can get away with setting to 5min but on hotter days it works best at 15 or more.Business, Economics, and Finance. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. Crypto cars for sale boise craigslistnew construction homes in fort myers florida under dollar250khisense model ap10cr1w Set ecobee fan run time with temp/binary sensor threshold. Just started out with Home Assistant and trying to get an ecobee thermostat to change the fan minimum on time when the attic temperature is within a certain threshold (AC/furnace and ducting are in the attic, so can't let unconditioned air circulate during the day). maggiano's reheat pasta Are there cases when setting the fan runtime per hour makes sense? I currently have it set to 5 minutes/hour to help even out the heat in the house during winter. But in the summer, it's running against a humidified evap coil (outside cooling runs)...which is not ideal for indoor humidity control?Aux Heat Runtime Alert: Alerts you if the Auxiliary heat source runs for more than the set amount in a 24-hour period. This is set to 3 hours by default. This is set to 3 hours by default. Aux Outdoor Temp Alert: Alerts you if the auxiliary heat is called for when the outdoor temperature exceeds this setpoint. rayus radiology lafayettearamark holiday calendar 2023simplenursing discount code To begin, go to Ecobee's website on any computer and click "Login" at the top. Unfortunately, the only way to view your Ecobee's usage history and reports is through the web interface. Enter in your username and password, and then click "Sign In". Click on "Home IQ". If you see the below screen, it means that your Ecobee hasn't been in use for ...